Purevolt Purevolt Purevolt
Purevolt is an ISO 9001-2000 Certified Co. and Registered with Govt. Bodies DGS&D & NSIC.
» Home
» Profile
» Clients
» Certification
» Download
» Contact Us
» Query
Our Products
» Servo Voltage Stabilizer
» Online UPS
» Offline UPS
» Inverter (DC-AC Converter)
» Automatic Voltage Stabilizer
» Constant Voltage Transformer (CVT)
» Isolation Transformer
» Variable Auto Transformer (Variacs)
Digital Power Inverter (Executive Series)

Purevolt’s Digital Power Inverter is the surest bet to mend your summers with peace. Other than supplying power, it does not make it's presence felt, Smart, Elegant, Sturdy and Reliable every Inverter is built to provide unbeatable performance. Purevolt digital power inverter is a 3-function DC-to-AC inverter with auto AC-to-battery transfer and integrated charging system serves as an extended run stand-alone powers source for a household or industrial inverter. These Digital Inverters are designed to meet Global requirements for power failure where not only the product reliability but design & look also matters. This Executive Series is available in different ranges from 2000 VA to 5500 VA.

DC - AC ConverterOPERATIONS of our DC – AC Converter

In case of power failure or the Mains voltage being out of range, the DC-to-AC Inverter will switch to backup mode The Load connected through Inverter will remain operative subject to the condition that Total Load is not more than Rated Capacity. In case the Load is more than the Rated Capacity, the Inverter will turn “OFF” and start giving beep signals. It will turn “ON” after every few seconds (Appx.. 10-15 Sec) and check if the load is reduced within the limits. It will “SHUT OFF” again if load is still above the Rated Capacity. In case the Load exceeds the Capacity by more than 50% of the rated capacity, the inverter will remain “OFF”. It will start checking the Load only when it is brought down to the rated capacity or Max. 10 % more. In battery mode if the batteries are in charged conditions, the Inverter will continue to give Output. When the battery voltage drops below required voltage (ie. The batteries are discharged) then the Inverter will display “Switch Off Battery Low” & automatically “SHUTS OFF” the output voltage. It will start giving buzzer sound. It is important to “TURN OFF” the Inverter switch in this condition because batteries would still be drained slowly to support the Buzzer & display. When Mains A.C. is restored, “TURN ON” the Inverter Switch to allow automatic changeover during mains failure.

Rating available: 2000 VA – 5500 VA
Click Here for Technical Specifications



Home | Profile | Clients | Certifications | Download | Contact Us | Query
Copyright © Pure Volt. All Rights Reserved
Site Developed & Promoted by Gnext Technologies